Air curtains are widely used in commercial buildings, industrial facilities, food-processing plants, cleanrooms, and other environments where temperature separation and air exchange control are important. By generating a high-speed air stream across an entrance, an air curtain helps reduce the exchange of indoor and outdoor air when doors are open.
However, the continuous operation of an air curtain also places thermal demands on its internal electrical and control components. Motor drivers, power supplies, control boards, and other electronic components may generate heat during extended operation. If heat cannot be dissipated effectively, component temperatures may rise, potentially affecting system reliability and service life.
This article examines the thermal management requirements of air curtains, explains the role of auxiliary cooling fans in internal electrical compartments, and introduces SANYO DENKI San Ace 80 × 80 × 38 mm DC axial fans as potential cooling solutions for air curtain control systems.
Keywords: SANYO DENKI San Ace, air curtain cooling, 80 × 80 × 38 mm fan, DC axial fan, auxiliary cooling, thermal management
An air curtain is an air distribution device installed above or beside an entrance. It produces a directed airflow that forms an air barrier across the opening.
When a door or entrance is open, the air curtain helps reduce the exchange of indoor and outdoor air. Depending on the application, it can help limit the entry of hot air, cold air, dust, insects, and other airborne contaminants.
Air curtains are commonly used in:
Commercial entrances and shopping malls
Warehouses and logistics centers
Food-processing facilities and cold storage areas
Industrial workshops
Hospitals and laboratories
Cleanrooms and temperature-controlled environments
The main airflow in an air curtain is generally generated by a dedicated high-volume fan or blower assembly. Its primary function is to create the air barrier at the entrance.
It is important to distinguish this main airflow system from the auxiliary cooling fans used inside the air curtain. Small DC axial fans, such as the SANYO DENKI San Ace 80 × 80 × 38 mm series, are more suitable for cooling internal electrical compartments, motor drivers, and control electronics. They are not intended to replace the main air curtain blower.
Although an air curtain is designed primarily for airflow separation, its internal electrical components also require effective heat dissipation.
During continuous operation, several components may generate heat:
| Component | Main heat source | Potential thermal impact |
|---|---|---|
| Motor driver | Power switching and current losses | Increased semiconductor temperature |
| Power supply | Conversion losses | Reduced power supply reliability |
| Control board | Electronic component operation | Temperature-related performance degradation |
| Motor assembly | Winding and mechanical losses | Increased operating temperature |
| Electrical connectors | Contact resistance and current loading | Localized temperature rise |
In applications such as warehouse entrances, industrial workshops, and commercial buildings, air curtains may operate for extended periods or switch on and off frequently in response to door activity.
If the internal enclosure has limited ventilation, heat can accumulate around the electronic components. This may lead to:
Higher operating temperatures inside the electrical compartment.
Increased thermal stress on power semiconductors and capacitors.
Reduced reliability of electronic control components.
Increased risk of temperature-related failures.
Greater maintenance requirements over the equipment's service life.
Therefore, thermal management should be considered as part of the overall air curtain design, rather than as an afterthought.
One of the common environmental challenges around air curtain installations is the temperature and humidity difference between indoor and outdoor air.
For example, during summer, warm and humid outdoor air may enter a temperature-controlled building. In winter, cold outdoor air may meet warm indoor air around the entrance.
These conditions can create localized temperature and humidity variations. When the surface temperature of a component falls below the dew point of the surrounding air, condensation may occur.
Condensation can be particularly concerning around:
Electrical control compartments
Power supply modules
Circuit boards and connectors
Metal enclosure surfaces
Cable entry points
Moisture may contribute to corrosion, insulation degradation, and electrical reliability problems if the equipment is not adequately protected.
However, it is important to understand that an auxiliary cooling fan alone cannot guarantee the prevention or elimination of condensation. Condensation is governed by factors including air temperature, relative humidity, surface temperature, and dew point.
A more comprehensive protection strategy may include:
Appropriate enclosure sealing and insulation
Effective drainage and moisture management
Protective coatings and corrosion-resistant materials
Suitable component selection
Temperature and humidity monitoring
Control strategies based on actual operating conditions
Auxiliary airflow can help improve heat distribution and reduce localized heat accumulation, but it should be evaluated as one part of the overall thermal and moisture protection strategy.
The main blower of an air curtain is responsible for producing the air barrier. However, the electrical compartment has a different thermal management requirement.
Its cooling design must consider the heat generated by internal components, the available installation space, airflow paths, and the resistance created by protective structures.
An auxiliary DC axial fan can help:
Promote air circulation within the electrical compartment.
Remove heat from motor drivers and power supply modules.
Reduce localized temperature accumulation.
Improve airflow around heat-generating components.
Support more stable operating temperatures under continuous operation.
The actual cooling effect depends on the fan's operating point and the airflow resistance of the enclosure.
A fan's rated maximum airflow should not be interpreted as the actual airflow inside the equipment. Filters, protective grilles, narrow air passages, and internal components all create resistance. Therefore, fan selection should be based on the system resistance curve and the fan's P-Q performance curve.
For air curtain electrical compartments requiring compact, high-performance auxiliary cooling, the SANYO DENKI San Ace 80 × 80 × 38 mm DC axial fan series offers several performance options.
Different models provide different combinations of airflow, static pressure, rotational speed, power consumption, and noise levels. This allows designers to select a fan according to the actual thermal requirements and internal airflow resistance of the equipment.
The following table lists representative 80 × 80 × 38 mm models for preliminary comparison.
| Model | Rated Voltage | Rated Current | Maximum Airflow | Maximum Static Pressure | Noise |
|---|---|---|---|---|---|
| 9HVB0812P1S001 | 12 V DC | 3.8 A | 3.7 m³/min | 1,400 Pa | 73 dB(A) |
| 9HV0812P1G601 | 12 V DC | 3.4 A | 3.7 m³/min | 1,000 Pa | 69 dB(A) |
| 9GA0812P1S61 | 12 V DC | 0.94 A | 2.6 m³/min | 480 Pa | 59 dB(A) |
| 9RA0812P1H001 | 12 V DC | 0.66 A | 2.19 m³/min | 168 Pa | 46 dB(A) |
Note: The values above are representative specifications for model comparison. Always refer to the manufacturer's datasheet for the exact model suffix, electrical characteristics, performance curves, and operating conditions before final selection.
The 9HVB series is suitable for applications where relatively high airflow and static pressure are required.
For example, the 9HVB0812P1S001 offers:
Rated voltage: 12 V DC
Rated current: 3.8 A
Rated power: 45.6 W
Rotational speed: 16,800 min⁻¹
Maximum airflow: 3.7 m³/min
Maximum static pressure: 1,400 Pa
Noise level: 73 dB(A)
PWM speed control
Pulse sensor output
This type of fan may be considered for compact electrical compartments with relatively high airflow resistance, provided that the power supply, noise limits, mounting structure, and actual operating point are compatible.
The 9HV series provides another option for applications requiring a combination of airflow and static pressure.
The 9HV0812P1G601 is a representative model with a maximum airflow of approximately 3.7 m³/min and a maximum static pressure of 1,000 Pa.
For air curtain electrical compartments, this performance range may be worth evaluating when internal airflow paths include protective grilles, narrow passages, or other restrictions.
The 9GA0812P1S61 provides a lower-power alternative compared with the high-performance models listed above.
Its representative specifications include:
Rated voltage: 12 V DC
Rated current: 0.94 A
Rated power: 11.28 W
Rotational speed: 9,550 min⁻¹
Maximum airflow: 2.6 m³/min
Maximum static pressure: 480 Pa
Noise level: 59 dB(A)
PWM speed control
Pulse sensor output
For equipment with moderate heat dissipation requirements, the 9GA series may provide a suitable balance between airflow performance and electrical power consumption.
In applications where noise is an important design consideration, the 9RA0812P1H001 may be considered.
Its representative specifications include:
Rated voltage: 12 V DC
Rated current: 0.66 A
Rated power: 7.92 W
Rotational speed: 6,100 min⁻¹
Maximum airflow: 2.19 m³/min
Maximum static pressure: 168 Pa
Noise level: 46 dB(A)
Compared with higher-speed models, this option offers a lower noise level and lower power consumption. However, its lower static pressure means that the enclosure airflow resistance must be carefully evaluated.
A low-noise fan is not necessarily the best choice if it cannot deliver sufficient airflow at the required system operating point.

Selecting an auxiliary cooling fan requires more than comparing maximum airflow or rotational speed. The following factors should be considered together.
First, identify the heat-generating components inside the air curtain.
The design team should evaluate:
Power consumption of the motor driver
Power supply conversion losses
Heat generated by control electronics
Operating duration and duty cycle
Maximum allowable component temperatures
Ambient temperature around the installation
The required cooling airflow should be determined according to the total heat load and the allowable temperature rise.
The internal structure of the electrical compartment has a direct influence on the actual airflow delivered by the fan.
Potential sources of resistance include:
Protective grilles
Dust filters
Narrow air passages
Cable bundles
Internal partitions
Heat sinks and electronic modules
A fan with a high maximum airflow rating may still deliver insufficient airflow if the system resistance is too high.
Therefore, the actual operating point should be determined using the fan's P-Q curve and the system resistance curve.
The maximum airflow and maximum static pressure are two different operating endpoints. They cannot normally be achieved simultaneously.
The maximum airflow is measured under a condition close to free-air delivery, while the maximum static pressure is measured at zero airflow. The actual airflow in the equipment is determined by the intersection of the fan performance curve and the system resistance curve.
The 80 × 80 × 38 mm San Ace series includes models with different electrical specifications.
Before selecting a model, verify:
Rated supply voltage: 12 V, 24 V, or 48 V DC, depending on the model
Rated current and power consumption
Available power supply capacity
Startup current and voltage stability
Connector type and wiring definition
Polarity and electrical protection requirements
The selected fan must be compatible with the air curtain's power supply and control system.
Some San Ace models support PWM speed control and pulse sensor output.
PWM control allows the fan speed to be adjusted according to the thermal requirements of the equipment. For example, the control system may increase fan speed when the internal temperature rises and reduce speed when the cooling demand decreases.
Pulse sensor output can provide rotational speed feedback for monitoring purposes.
These functions may help equipment designers implement more flexible thermal management strategies, including:
Temperature-based fan speed control
Fan rotation monitoring
Abnormal-speed detection
Maintenance alerts
Energy-saving operation
However, the electrical interface, PWM frequency, signal level, and pulse output definition must be checked against the manufacturer's datasheet and the equipment controller.
Although the models share an 80 × 80 × 38 mm nominal frame size, mechanical details may differ.
Before installation, verify:
Mounting hole dimensions
Fan rotation direction
Airflow direction
Ribbed or ribless frame construction
Connector and cable position
Available installation depth
Clearance around the fan inlet and outlet
The exact model drawing should be checked to avoid installation interference or airflow obstruction.
A suitable fan selection should be validated under the actual operating conditions of the air curtain.
Recommended evaluation items include:
| Test Item | Purpose |
|---|---|
| Temperature-rise test | Verify the temperature of internal components under operating conditions |
| Airflow verification | Confirm that the fan delivers sufficient airflow inside the enclosure |
| Noise test | Evaluate the acoustic impact of auxiliary cooling |
| Continuous operation test | Assess performance during extended operation |
| Startup test | Verify reliable startup under different operating conditions |
| PWM control test | Confirm speed adjustment and control stability |
| Pulse feedback test | Verify rotational speed monitoring |
| Environmental test | Evaluate performance under the specified temperature and humidity conditions |
For equipment installed near frequently opened entrances, environmental conditions may change considerably throughout the day.
Testing should therefore consider realistic operating scenarios, including changes in ambient temperature, humidity, door-opening frequency, and equipment load.
Where condensation is a concern, the design should also be evaluated for moisture protection, drainage, insulation, and electrical safety. A cooling fan should not be treated as a standalone condensation-control solution.
An air curtain is designed to create an airflow barrier across an entrance, but its internal electrical and control systems also require appropriate thermal management.
Motor drivers, power supplies, and control electronics can generate heat during continuous operation. Without sufficient ventilation, localized temperature accumulation may affect component reliability and equipment service life.
The SANYO DENKI San Ace 80 × 80 × 38 mm DC axial fan series provides several performance options for auxiliary cooling applications. Depending on the actual heat load, airflow resistance, noise requirements, and electrical conditions, equipment designers can evaluate different models from the 9HVB, 9HV, 9GA, and 9RA series.
The key to successful selection is not simply choosing the fan with the highest airflow or static pressure. It is matching the fan's performance curve to the actual system resistance and verifying the cooling effect through equipment-level testing.
Shenzhen JENTECH Electronics Co., Ltd. specializes in industrial cooling fans and thermal management solutions. The company provides cooling fan selection, product matching, technical support, and supply services for customers across a wide range of industrial applications.
With long-term cooperation in the SANYO DENKI San Ace product range, JENTECH supports customers in evaluating suitable fan models for applications such as industrial equipment, power electronics, communication systems, automation equipment, and air curtain electrical compartments.
If you are selecting an 80 × 80 × 38 mm DC axial fan for an air curtain or another industrial cooling application, contact JENTECH for model recommendations and technical support.