| Specification Item | Parameter Value | Specification Item | Parameter Value |
|---|---|---|---|
| Model Number | 109P0405F3013 | Frame Size | 40 mm |
| Frame Thickness | 28 mm | Frame Material | Plastic |
| Rated Voltage | 5 V | Operating Voltage Range | 4.5 V ~ 5.5 V |
| Rated Current | 0.28 A | Rated Input Power | 1.4 W |
| Rated Speed | 6700 min-1 | Maximum Airflow | 0.244 m3/min |
| Max Airflow (CFM) | 8.6 CFM | Max Static Pressure | 58.8 Pa |
| Max Static Pressure (inchH2O) | 0.236 inchH2O | Sound Pressure Level | 30 dB(A) |
| Operating Temperature Range | -20 ℃ ~ +70 ℃ | Expected Service Life | 60000 hours at 40℃, 90000 hours at 40℃ |
| Net Mass | 52 g | Speed Sensor Type | Pulse sensor (tachometer output) |
| PWM Control Function | Not Supported | Ribbed Frame Structure | Yes |
| Performance Index | Data Explanation | Application Advantage |
|---|---|---|
| Rotational Speed 6700 RPM | Stable rated speed under 5V rated voltage, consistent airflow output without speed fluctuation | Stable heat dissipation for continuous running server hardware |
| Max Airflow 8.6 CFM | Large air delivery volume within 4028 compact size, fast hot air exhaust | Solve heat accumulation of dense circuit boards |
| Max Static Pressure 58.8 Pa | Excellent pressure resistance, air can pass through dense heat sink fins | Adapt to equipment with dense internal shielding and radiators |
| Noise Level 30 dB(A) | Low noise design at full speed, no harsh running sound | Suitable for office environment industrial hosts and low noise server cabinets |
| Pulse Tachometer Sensor | Output pulse signal corresponding to fan rotation speed, host system can read real-time fan speed | Support fan fault alarm, avoid equipment overheating damage caused by fan stall |
| Environment Parameter | Standard Parameter | Life Performance |
|---|---|---|
| Operating Temperature | -20℃ to 70℃ | Normal continuous operation in cold outdoor equipment and high temperature closed cabinet |
| Reference Service Life Condition 1 | Ambient temperature 40℃ | 60000 hours average service life |
| Reference Service Life Condition 2 | Ambient temperature 40℃ | 90000 hours extended service life under light load |
| Storage Temperature | Match operating temperature range | No permanent performance attenuation after long-term storage |
| Category | Detail Content | Practical Value |
|---|---|---|
| Global Safety Certifications | UL ratings, CSA standards, EN standards | Can be directly installed on equipment exported to North America and European markets without secondary certification |
| Environmental Compliance | RoHS directive | No hazardous heavy metal materials, meet EU environmental access rules |
| Frame Structure | Ribbed plastic frame | Improve frame anti-deformation ability, increase static pressure, reduce vibration during operation |
| Control Interface | No PWM speed regulation function | Fixed speed stable operation design, simplify circuit control scheme for basic cooling equipment |
Contact: Mr. Wang
Phone: 18038149909
Tel: 0755-23706799
Email: whd@jentech.cn
Add: No. 28, Tongyuwu Industrial Zone, Kuikeng Community, Guanlan Street, Longhua District, Shenzhen City. 6th floor, Building 1, Hualangjia Industrial Park



Click to inquire